ASCE-7 Wind Zone 4-5 Interpolation Calculator

Important Message from Engineering Express

By clicking below, you agree that the use of this design aid is for estimating purposes only. Results are not valid for use & no construction or design shall be performed without the review and certification by a registered professional engineer.

No warranty or guarantee whatsoever is offered with any results obtained herein.


AGREE & CONTINUE

This tool assists in interpolating between the corner & interior wall wind zones 4 and 5 using ASCE 7.

Typically zone 5 corner negative (suction) pressures are higher than a building’s interior zone 4 pressures which may restrict the glazing product from being installed.

Using this tool, interpolated pressures can be determined that may permit a lower product limiting pressure.

Results could be reviewed and certified for permit by an engineer of this firm by requesting a review & certified results.

Ref: FBC HVHZ 2411.  Click Here for an explanation of wall zones 4 & 5

Zone interpolator
ASCE 7 WIND PRESSURE ZONE 4/5 INTERPOLATOR
SEE HELP & IMAGE AT BOTTOM - HOVER/CLICK LABELS FOR HELP
Click to read our informative help page on this tool.
INPUTS
This is the average roof height from the peak to the eave. See image below. Mean Roof Height
FT
This is the shortest building dimension. The End zone 5 is 10% of this value, 40% of height, but not less than 3’. See help and image below. Min Bldg Dimension
FT
This is the distance from the nearst building corner to the edge of the window being installed. See image below. Distance To corner
FT
This is the horizontal distance of the window being insalled. See image below. Opening Width
Inches
Zone 4  + Pressure
PSF
Absolute value of the negative zone 4 pressure only (do not include the negative sign). Zone 4 - Pressure
PSF
Zone 5 + Pressure
PSF
Absolute value of the negative zone 5 pressure only (do not include negative sign). Zone 5 - Pressure
PSF
INTERPOLATED OUTPUT
% In Zone 4

INVALID WITHOUT
ENGINEER SEAL

%
% In Zone 5
%
Negative Pressure
PSF
Positive Pressure
PSF
© Engineering Express

ASCE-7 Wind Zone 4-5 Interpolation Calculator

$80.00$120.00

This tool interpolates between the corner & interior wall wind zones 4 &5 using ASCE 7-16 or ASCE 7-10. Results can be reviewed & certified by an engineer for permit.

Read More
Please select the state you would like the document certified in
Please choose whether this is for a multi-story building or not
This field can't be Empty
This field can't be Empty
Please choose the permitting party
This field can't be Empty
When choosing Sealed Hardcopy, maximum quantity is 1.
3 copies are sent per order.
Save up to an additional 33% by using tokens Learn more

As of November 1, 2024, All building departments in Broward county require files submitted to their online permitting portal to be formatted differently.

Need the drawing earlier than 24 hours? We now have the option to expedite it for a fee! Please note expedited orders only applies during our business hours. Any orders placed over the weekend and or after business hours with the expedition fee will be applied to the next business day.

Plan Format

Digitally Sealed Online-Only File, Raised Sealed Embossed Physical Copy

The document you are purchasing is a generic performance evaluation. Use of this document for any site-specific application is the responsibility of others. Installations beyond the performance limitations listed within the purchased document, any site-specific designs/certifications, or California-specific projects shall require custom engineering and invalidate the use of this evaluation. Learn more about the use of this document

Click here to request a quote for us to provide these services, which can also be provided by others who would then become responsible for the applicability of this evaluation. Contact Us if there are any questions and always consult with a design professional before using any generic performance evaluations with your project.