Miami Tech Mechanical Unit Stand Calculator

Important Message from Engineering Express

By clicking below, you agree that the use of this design aid is for estimating purposes only. Results are not valid for use & no construction or design shall be performed without the review and certification by a registered professional engineer.

No warranty or guarantee whatsoever is offered with any results obtained herein.


AGREE & CONTINUE
Miami Tech Stand Calculator 23-65660- V4.1 - NOA Fix
           
  Miami Tech Mechanical Unit Rooftop Stand Calculator  
  For Help, Hover & Click Labels, See Images Below, or Visit the Glossary  
   
  Select Stand Type  
 
 
Link to Applicable Florida State Approval
Link to applicable Miami Dade Notice Of Acceptance
Link to applicable Engineering Express Product
 
   
  Site Conditions
 
Input Ultimate Wind Speed, Vult, Based on Location. This can be found at asce7hazardtool.online and is also subject to your local building department requirements
 
 
Determine your site exposure category. For coastal areas, use Exposure D. Help can be found at ecalc.io/Exposure
 
 
 
Input the tallest elevation that units will be installed at (measured from finished grade = 0ft) Roof Installation Height (ft)
 
 
Wind Pressure Values calculated per ASCE 7-16 & 7-22, ch 29.4. Both Lateral and Uplift forces considered. Design Wind Pressure
Lateral Uplift  
   
           
  Mechanical Unit Informaiton
 
How many units are installed on the stand being designed?
For stands with more than 5 units, site specific design required.
How Many Units?
   
 
 
Input the average spacing between units. Spacing will be considered between each unit for calculation of total stand width. Spacing Between Units
   
   
Max Width 60" Width
Unit Depth may be max 12" larger than Stand Depth
(Max 6" cantilever on each side). Unit integrity by others.
Depth
Max Height 60" Height
 
  Unit #1  
  Unit #2  
  Unit #3  
  Unit #4  
  Unit #5  
 
Total Stand Width considers width of all units, average spacing between units, and 6" width on each side of end units. Total Stand Width
     
  Total Face Area      
  Unit Depth may be up to 12" larger than Stand Depth  
  (Max 6" cantilever on front & back). Unit integrity by others.   
  Individual Unit Weight to be between 75 lbs & 450 lbs each  
           
  Stand & Rail Information
  Stand Selected Above  
  Stand Post Height  
 
  Stand Depth  
 
           
  Required # of Frames  
 
Refer Miami Tech Product Information documents to confirm required post product number. Beam lengths to be determined separately. Post Part #s
   
 
Refer Miami Tech Product Information documents to confirm required Cross Bracre product number. For AST system, angle length is determined by the distance between center webbing of I beams Cross Brace Part #s
   
 
Link to Applicable Florida State Approval Corresponding FSA
 
 
Link to applicable Miami Dade Notice Of Acceptance Corresponding NOA
 
 
Link to applicable Engineering Express Product Corresponding EX#
 
   
  Version 3.1  
  © Engineering Express   Updated 11/22/2023  

Miami Tech Mechanical Unit Stand Calculator

$150.00 or ( 15 Tokens )

Miami Tech Mechanical Unit Stand Calculator

Read More
Please select the state you would like the document certified in
This field can't be Empty
This field can't be Empty
This field can't be Empty
When choosing Sealed Hardcopy, maximum quantity is 1.
3 copies are sent per order.
Save up to an additional 33% by using tokens Learn more

As of November 1, 2024, All building departments in Broward county require files submitted to their online permitting portal to be formatted differently.

Weight N/A
Dimensions N/A
Plan Format

Digitally Sealed Online-Only File, Raised Sealed Physical Copy

The document you are purchasing is a generic performance evaluation. Use of this document for any site-specific application is the responsibility of others. Installations beyond the performance limitations listed within the purchased document, any site-specific designs/certifications, or California-specific projects shall require custom engineering and invalidate the use of this evaluation. Learn more about the use of this document

Click here to request a quote for us to provide these services, which can also be provided by others who would then become responsible for the applicability of this evaluation. Contact Us if there are any questions and always consult with a design professional before using any generic performance evaluations with your project.